Options and Accessories for UDS

Configuration

  • Chase style – Standard flat top, option to have it peaked
  • Riser termination –  An adjustable height collar (78 to 84 inch) is provided. If required, an optional riser extension is available at specified heights
  • Special configurations – are available, please contact your Accurex representative for details

Gas

  • Drop size – 1-inch diameter drops available. Alternating 0.75 and 1.25 are standard
  • Quick disconnect hoses – provide an easy method of connecting or disconnecting gas lines (available in 48, 60, and 72 inch lengths)
  • Restraint cables – prevent cooking equipment from being moved without disconnecting the gas line
  • Main ball valve – on incoming service to turn gas off at the unit
  • Fire system gas valve – mechanical or electric with manual reset gas valves can be mounted in the unit to turn off gas in fire mode
  • Battery backup for gas solenoid – is available for your gas utilities
  • Ball valves – available from 0.5 inch to 1.25 inch for shut off at each connection along the chase

Water

  • Main ball valves – on incoming service to provide a main shut off at the unit
  • Gauges – are available for either pressure/temperature or pressure only
  • Fill faucet – (T & S B-0610 Faucet) with 60 inch hose
  • Water hoses – come in lengths of 48, 60 or 72 inches
  • Water filters – are available in single appliance and multiple appliance styles
  • Hot and cold water drops – are in 0.75 inch diameter and are placed every 24 inches
  • Shock arrestors – to prevent water hammering that typically occurs when the water is shut off
  • Pressure reducing valve – is used when the water pressure entering the UDS is too high. The reducer valve reduces the pressure to an appropriate level (typically 40-60 psi)
  • Hand sink – (mounted on the riser) is available. Sink is 12 inches wide
  • Hose reel assembly – Mounted on one of the risers is available for auxiliary hoses
  • Ball valves – available from 0.25 inch to 0.75 inch for shut off at each connection along the chase

Electrical

Primary Electrical Service – Choose from panel board or point of use breakers. Main breaker and branch breakers, including ground fault protection, is provided with primary electrical service (see table below for available sizes)

Breaker Voltage Phase Min Size (Amp) Max Size (Amp)

Main

120 or 208

1 or 3

40

400

Branch

120

1

20

50

Branch

208

1

20

100

Branch

208

3

20

225

Electrical receptacles – are 120 V or 208 V based on need and the receptacles NEMA configuration is straight blade with an available twist lock option in 120/1 - 20A GFCI (GFCI not available with twist lock)

Controls – for the primary electrical service option include status lights, fire system connection, light or fan (switches), gas solenoid control panel (with a solenoid gas valve), emergency shut down and pre-wired tempering switch (if required)

Breaker Voltage Phase Min Size (Amp) Max Size (Amp)

Main

480 or 208

3

40

400

Branch

120

1

20

50

Branch

208

1

20

100

Branch

208

3

20

225

Branch

480

3

20

225

Secondary Electrical Service – Choose from panel board or point of use breakers. Main breaker and branch breakers, including ground fault protection, is provided with primary electrical service. See table below for available sizes

Additional Utilities and Options

  • Prison package
  • Steam/condensate system
  • Chilled water line with insulation
  • Compressed air line
  • Gasketed construction
  • Weatherproof receptacle/switch covers
  • While-in-use receptacle covers
  • 12-inch by 12-inch viewing window in riser
  • Hinged access doors
  • Water filter bracket on chase

Please contact your Accurex representative for more information